1
2Canon MP620 USB 2.0 port
3
4~> listusb
504a9:172f /dev/bus/usb/2/0/5 "Canon, Inc." "PIXMA MP620" ver. 0109
6
7~> Sanity
8device `pixma:04A9172F_164654' is a CANON Canon PIXMA MP620 multi-function peripheral
9BMessage('sdvn') {
10 device = string("pixma:04A9172F_164654", 22 bytes)
11}
12checking dev 0
13BMessage('sdev') {
14 device = (type = 'PNTR')(size = 8)
15}
16CMP: pixma:04A9172F_164654:pixma:04A9172F_164654
17[Option # 2]
18 name: resolution
19 title: Scan resolution
20 desc: Sets the resolution of the scanned image.
21 type: SANE_TYPE_INT
22 unit: SANE_UNIT_DPI(dpi)
23 size: 4
24 caps: SANE_CAP_SOFT_SELECT SANE_CAP_SOFT_DETECT SANE_CAP_AUTOMATIC
25 constraint: SANE_CONSTRAINT_WORD_LIST
26 auto||75|150|300|600|1200dpi [75]
27[Option # 3]
28 name: mode
29 title: Scan mode
30 desc: Selects the scan mode (e.g., lineart, monochrome, or color).
31 type: SANE_TYPE_STRING
32 unit: SANE_UNIT_NONE
33 size: 31
34 caps: SANE_CAP_SOFT_SELECT SANE_CAP_SOFT_DETECT SANE_CAP_AUTOMATIC
35 constraint: SANE_CONSTRAINT_STRING_LIST
36 auto|Color|Gray|Lineart [Color]
37[Option # 4]
38 name: source
39 title: Scan source
40 desc: Selects the scan source (such as a document-feeder). Set source before mode and resolution. Resets mode and resolution to auto values.
41 type: SANE_TYPE_STRING
42 unit: SANE_UNIT_NONE
43 size: 31
44 caps: SANE_CAP_SOFT_SELECT SANE_CAP_SOFT_DETECT
45 constraint: SANE_CONSTRAINT_STRING_LIST
46 Flatbed [Flatbed]
47[Option # 5]
48 name: button-controlled
49 title: Button-controlled scan
50 desc: When enabled, scan process will not start immediately. To proceed, press "SCAN" button (for MP150) or "COLOR" button (for other models). To cancel, press "GRAY" button.
51 type: SANE_TYPE_BOOL
52 unit: SANE_UNIT_NONE
53 size: 4
54 caps: SANE_CAP_SOFT_SELECT SANE_CAP_SOFT_DETECT
55 constraint: SANE_CONSTRAINT_NONE
56 [=(yes|no)] [no]
57[Option # 7]
58 name: custom-gamma
59 title: Use custom gamma table
60 desc: Determines whether a builtin or a custom gamma-table should be used.
61 type: SANE_TYPE_BOOL
62 unit: SANE_UNIT_NONE
63 size: 4
64 caps: SANE_CAP_SOFT_SELECT SANE_CAP_SOFT_DETECT SANE_CAP_AUTOMATIC
65 constraint: SANE_CONSTRAINT_NONE
66 [=(auto|yes|no)] [yes]
67[Option # 8]
68 name: gamma-table
69 title: Image intensity
70 desc: Gamma-correction table. In color mode this option equally affects the red, green, and blue channels simultaneously (i.e., it is an intensity gamma table).
71 type: SANE_TYPE_INT
72 unit: SANE_UNIT_NONE
73 size: 16384
74 caps: SANE_CAP_SOFT_SELECT SANE_CAP_SOFT_DETECT SANE_CAP_AUTOMATIC
75 constraint: SANE_CONSTRAINT_RANGE
76 auto|0..0,...
77[Option # 9]
78 name: gamma
79 title: Gamma function exponent
80 desc: Changes intensity of midtones
81 type: SANE_TYPE_FIXED
82 unit: SANE_UNIT_NONE
83 size: 4
84 caps: SANE_CAP_SOFT_SELECT SANE_CAP_SOFT_DETECT SANE_CAP_AUTOMATIC
85 constraint: SANE_CONSTRAINT_RANGE
86 auto|0.299988..5 [2.2]
87[Option # 11]
88 name: tl-x
89 title: Top-left x
90 desc: Top-left x position of scan area.
91 type: SANE_TYPE_FIXED
92 unit: SANE_UNIT_MM(mm)
93 size: 4
94 caps: SANE_CAP_SOFT_SELECT SANE_CAP_SOFT_DETECT SANE_CAP_AUTOMATIC
95 constraint: SANE_CONSTRAINT_RANGE
96 auto|0..216.069mm [0]
97[Option # 12]
98 name: tl-y
99 title: Top-left y
100 desc: Top-left y position of scan area.
101 type: SANE_TYPE_FIXED
102 unit: SANE_UNIT_MM(mm)
103 size: 4
104 caps: SANE_CAP_SOFT_SELECT SANE_CAP_SOFT_DETECT SANE_CAP_AUTOMATIC
105 constraint: SANE_CONSTRAINT_RANGE
106 auto|0..297.011mm [0]
107[Option # 13]
108 name: br-x
109 title: Bottom-right x
110 desc: Bottom-right x position of scan area.
111 type: SANE_TYPE_FIXED
112 unit: SANE_UNIT_MM(mm)
113 size: 4
114 caps: SANE_CAP_SOFT_SELECT SANE_CAP_SOFT_DETECT SANE_CAP_AUTOMATIC
115 constraint: SANE_CONSTRAINT_RANGE
116 auto|0..216.069mm [216.069]
117[Option # 14]
118 name: br-y
119 title: Bottom-right y
120 desc: Bottom-right y position of scan area.
121 type: SANE_TYPE_FIXED
122 unit: SANE_UNIT_MM(mm)
123 size: 4
124 caps: SANE_CAP_SOFT_SELECT SANE_CAP_SOFT_DETECT SANE_CAP_AUTOMATIC
125 constraint: SANE_CONSTRAINT_RANGE
126 auto|0..297.011mm [297.011]
127[Option # 16]
128 name: button-update
129 title: Update button state
130 desc: Update button state
131 type: SANE_TYPE_BUTTON
132 unit: SANE_UNIT_NONE
133 size: 0
134 caps: SANE_CAP_SOFT_SELECT SANE_CAP_SOFT_DETECT SANE_CAP_ADVANCED
135 constraint: SANE_CONSTRAINT_NONE
136
137[Option # 17]
138 name: button-1
139 title: Button 1
140 desc: Button 1
141 type: SANE_TYPE_INT
142 unit: SANE_UNIT_NONE
143 size: 4
144 caps: SANE_CAP_SOFT_DETECT SANE_CAP_ADVANCED
145 constraint: SANE_CONSTRAINT_NONE
146 <int> [0]
147[Option # 18]
148 name: button-2
149 title: Button 2
150 desc: Button 2
151 type: SANE_TYPE_INT
152 unit: SANE_UNIT_NONE
153 size: 4
154 caps: SANE_CAP_SOFT_DETECT SANE_CAP_ADVANCED
155 constraint: SANE_CONSTRAINT_NONE
156 <int> [0]
157[Option # 19]
158 name: original
159 title: Type of original to scan
160 desc: Type of original to scan
161 type: SANE_TYPE_INT
162 unit: SANE_UNIT_NONE
163 size: 4
164 caps: SANE_CAP_SOFT_DETECT SANE_CAP_ADVANCED
165 constraint: SANE_CONSTRAINT_NONE
166 <int> [0]
167[Option # 20]
168 name: target
169 title: Target operation type
170 desc: Target operation type
171 type: SANE_TYPE_INT
172 unit: SANE_UNIT_NONE
173 size: 4
174 caps: SANE_CAP_SOFT_DETECT SANE_CAP_ADVANCED
175 constraint: SANE_CONSTRAINT_NONE
176 <int> [0]
177[Option # 21]
178 name: scan-resolution
179 title: Scan resolution
180 desc: Scan resolution
181 type: SANE_TYPE_INT
182 unit: SANE_UNIT_NONE
183 size: 4
184 caps: SANE_CAP_SOFT_DETECT SANE_CAP_ADVANCED
185 constraint: SANE_CONSTRAINT_NONE
186 <int> [0]
187failed to set option --threshold to automatic (Invalid argument)
188[Option # 23]
189 name: threshold
190 title: Threshold
191 desc: Select minimum-brightness to get a white point
192 type: SANE_TYPE_INT
193 unit: SANE_UNIT_PERCENT(%)
194 size: 4
195 caps: SANE_CAP_SOFT_SELECT SANE_CAP_SOFT_DETECT SANE_CAP_AUTOMATIC SANE_CAP_INACTIVE
196 constraint: SANE_CONSTRAINT_RANGE
197 auto|0..100% (in steps of 1) [inactive]
198failed to set option --threshold-curve to automatic (Invalid argument)
199[Option # 24]
200 name: threshold-curve
201 title: Threshold curve
202 desc: Dynamic threshold curve, from light to dark, normally 50-65
203 type: SANE_TYPE_INT
204 unit: SANE_UNIT_NONE
205 size: 4
206 caps: SANE_CAP_SOFT_SELECT SANE_CAP_SOFT_DETECT SANE_CAP_AUTOMATIC SANE_CAP_INACTIVE
207 constraint: SANE_CONSTRAINT_RANGE
208 auto|0..127 (in steps of 1) [inactive]
209failed to set option --adf-wait to automatic (Invalid argument)
210[Option # 25]
211 name: adf-wait
212 title: ADF Waiting Time
213 desc: When set, the scanner searches the waiting time in seconds for a new document inserted into the automatic document feeder.
214 type: SANE_TYPE_INT
215 unit: SANE_UNIT_NONE
216 size: 4
217 caps: SANE_CAP_SOFT_SELECT SANE_CAP_SOFT_DETECT SANE_CAP_AUTOMATIC SANE_CAP_INACTIVE
218 constraint: SANE_CONSTRAINT_RANGE
219 auto|0..3600 (in steps of 1) [inactive]
220SANE_FRAME_RGB